Protective and safety equipment as well as components that facilitate servicing (e.g. non-return valves, safety valves, overflow valves, shut-off valves) must be installed in accordance with national regulations and standards.
The compressor in a S1155/S1255/F1155/F1255 is inverter-controlled. The compressor’s power is adapted according to the demand and routed to heating, hot water or pool heating. If the power is not sufficient for the heating demand, additional heating is connected automatically.
The compressor in a F1145/F1245 is the on/off type. The compressor’s full power is routed to heating, hot water or pool heating. If the power is not sufficient for the heating demand, additional heating is connected automatically.
The compressors in a F1345 are the on/off type. The compressor’s full power is routed to heating, hot water or pool heating. If the power is not sufficient for the heating demand, additional heating is connected automatically.
The compressors in a F1355 consist of one on/off type and one inverter-controlled compressor. The compressor’s power is adapted according to the demand and routed to heating, hot water or pool heating. If the power is not sufficient for the heating demand, additional heating is connected automatically.
The heat pump is supplied with a heating control system, which means that the heating supply to the house takes place in accordance with selected settings. For more information about heat production, see the Installer Manual.
The heat pump is supplied with a heating control system, which means that the heating supply to the house takes place in accordance with selected settings. When connecting to a system with thermostats on all radiators (or underfloor heating coils), either a bypass valve must be fitted or some of the thermostats must be removed to ensure there is sufficient flow. For more information about heat production, see the Installer Manual.
Multiple heat pumps can be interconnected, by selecting one heat pump as the master and the others as slaves. The heat pump is always delivered as the master heat pump, and up to 8 subordinate heat pumps can be connected to it and supply up to 540 kW (with 9 x F1345-60 kW) in the same system. In systems with several heat pumps, each pump is given a unique name. External temperature sensors and control signals must be connected solely to the primary heat pump, except for external control of the compressor module and reversing valve(s) (QN10), which can be connected one to each heat pump.
Hot water production takes place from the compressor(s) set to produce hot water.
When there is demand for hot water, the heat pump prioritises this and switches to hot water mode. There is no heat production in this mode.
With the AXC 50 accessory, F1345/F1355 can be used to heat one or more pools.
For further information, see the Installer Manual for the accessory.
POOL 40 is an accessory that enables pool heating with a compressor in your installation
For further information, see the Installer Manual for the accessory.
During pool operation and hot water production, you can choose which of the compressors will be responsible for operation. More compressor selections can be made.
Additional heat requires accessory AXC 40. AXC 40 can control step-controlled additional heat via a control signal. The additional heat is used for heat production.
For further information, see the Installer Manual for the accessory.
External, step-controlled additional heat can be controlled by up to three potential-free relays in F1345/F1355 (3 step linear or 7 step binary).
With the AXC 50 accessory, a further three potential-free relays can be used for additional heat control, which then gives max 3+3 linear or 7+7 binary steps.
Designation |
Name |
Specification |
RSK no. / Part no. |
Comments |
---|---|---|---|---|
-AA35-BT1 |
Outside sensor |
Included in F1345/F1355 |
||
-AA35-BT6 |
Controlling hot water sensor |
Included in F1345/F1355 |
||
-AA35-BT7 |
Display hot water sensor |
Included in F1345/F1355 |
||
-AA35-BT25 |
External supply temperature sensor |
Included in F1345/F1355 |
||
-AA35-BT63 |
External supply temperature sensor before QN10 |
Included in F1345/F1355 |
||
-AA35-BT71 |
External return line sensor |
Included in F1345/F1355 |
||
-AA35-GP10 |
External heating medium pump |
|||
-AA35-GP12.1 |
Charge pump for EB101 |
NIBE CPD 11 |
||
-AA35-GP12.2 |
Charge pump for EB102 |
NIBE CPD 11 |
||
-AA35-GP12.3 |
Charge pump for EB103 |
NIBE CPD 11 |
||
-AA35-GP12.4 |
Charge pump for EB104 |
NIBE CPD 11 |
||
-AA35-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-AA35-QN43 |
Bypass valve, cooling operation |
|||
-EB100 |
Heat pump system |
NIBE F1345/F1355 |
||
-EB100F1355 |
Heat pump system |
F1355 |
||
-EB100F1330 |
Heat pump system |
F1345-24/30 |
||
-EB100F1360 |
Heat pump system |
F1345-40/60 |
||
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EB100-BT1 |
Outside sensor |
Included in F1345/F1355 |
||
-BT1 |
Outside sensor |
Included in F1345/F1355 |
||
-BT6 |
Controlling hot water sensor |
Included in F1345/F1355 |
||
-EB100-BT6 |
Controlling hot water sensor |
Included in F1345/F1355 |
||
-EB100-BT7 |
Display hot water sensor |
Included in F1345/F1355 |
||
-BT7 |
Display hot water sensor |
Included in F1345/F1355 |
||
-EB100-BT25 |
External supply temperature sensor |
Included in F1345/F1355 |
||
-EB100-BT25_F1145 |
External supply temperature sensor |
Included in S1155/F1145/F1155 |
||
-EB100-BT25_F1245 |
External supply temperature sensor |
Included in S1255/F1245/F1255 |
||
-EB100-BT25_F1345 |
External supply temperature sensor |
Included in F1345/F1355 |
||
-BT25 |
External supply temperature sensor |
|||
-EB100-BT71 |
External return line sensor |
|||
-BT71 |
External return line sensor |
|||
-EB100-CM4 |
Expansion vessel, hot water |
Included in F1345/F1355 |
||
-EB100-FL1 |
Safety valve, hot water |
Included in F1345/F1355 |
||
-EB100-FL5 |
T&P valve |
Included in F1345/F1355 |
||
-EB100-FL6 |
Vacuum valve |
Included in F1345/F1355 |
||
-EB100-FQ1 |
Mixing valve |
Included in F1345/F1355 |
||
-EB100-QN17 |
Pressure reduction valve |
Included in F1345/F1355 |
||
-EB100-QM30 |
Shut-off valve |
|||
-EB100-RM1 |
Non-return valve |
|||
-EB100-WM3.1 |
Tundish, cold water |
Included in F1345/F1355 |
||
-EB100-WM3.2 |
Tundish, T&P valve |
Included in F1345/F1355 |
||
-EB100-GP7 |
External brine pump |
|||
-EB100-GP10 |
External heating medium pump |
|||
-GP10 |
External heating medium pump |
|||
-EB100-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-EP4 |
Heat exchanger, groundwater |
|||
-FL3_F1145 |
Safety valve, brine |
Included in S1155/F1155/F1145 |
||
-FL3_F1245 |
Safety valve, brine |
Included in S1255/F1255/F1245 |
||
-FL3 |
Safety valve, brine |
Included in F1345/F1355 |
||
-FL311xx |
Safety valve, brine |
Included in F1355/F1345-24/30/F1345/F1355 |
||
-FL10 |
Safety valve, brine |
|||
-FL10-0 |
Safety valve, brine |
|||
-FL11-0 |
Safety valve, brine |
|||
-FL12-0 |
Safety valve, heating medium |
|||
-FL13-0 |
Safety valve, heating medium |
|||
-HQ1-F1360 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ1-F1330 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ2-F1360 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ2-F1330 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ3-F1360 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ3-F1330 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-HQ4-F1360 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ4-F1330 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-GP16-0 |
Circulation pump, brine |
Included in F1345-24/30 40/60 |
||
-QN11 |
Shuttle valve |
|||
-QM12 |
Filling valve, brine |
|||
-QM21 |
Vent valve, brine |
|||
-QM31 |
Shut-off valve, heating medium supply line |
|||
-QM32 |
Shut-off valve, heating medium return line |
|||
-QM33 |
Shut-off valve, brine in |
|||
-QM34 |
Shut off valve, brine out |
|||
-QM40 |
Shut-off valve |
|||
-QM42 |
Shut-off valve, brine in |
|||
-QM50-0 |
Shut off valve, brine |
|||
-QM51-0 |
Shut off valve, brine |
|||
-QM52-0 |
Shut off valve, brine |
|||
-QM53-0 |
Shut off valve, brine |
|||
-QM54-0 |
Shut-off valve, heating medium |
|||
-QM55-0 |
Shut-off valve, heating medium |
|||
-QM56-0 |
Shut-off valve, heating medium |
|||
-QM57-0 |
Shut-off valve, heating medium |
|||
-QZ2 |
Filterball, heating medium |
Included in F1355 |
The F1345-24/30 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2_F1145 |
Filterball, heating medium |
Included in S1155/F1155 |
The F1145 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2_F1245 |
Filterball, heating medium |
Included in S1255/F1255 |
The F1245 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.1-0 |
Filterball, heating medium |
Included in F1355 |
||
-QZ2.2-0 |
Filterball, heating medium |
Included in F1355 |
||
-QZ2.3-0 |
Filterball, heating medium |
Included in F1355 |
||
-QZ2.4-0 |
Filterball, heating medium |
Included in F1355 |
||
-QZ3 |
Filterball, brine |
Included in F1355 |
The F1345-24/30 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ3_F1145 |
Filterball, brine |
Included in S1155/F1155 |
The F1145 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ3_F1245 |
Filterball, brine |
Included in S1255/F1255 |
The F1245 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ4 |
Filterball, heating medium |
Included in F1355 |
The F1345-24/30 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ5 |
Filterball, heating medium |
Included in F1355 |
The F1345-24/30 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-RM10-F1360 |
Non-return valve |
|||
-RM10-F1330 |
Non-return valve |
Included in F1345-24/30 |
||
-RM10-F1355 |
Non-return valve |
Included in F1355 |
||
-RM11-F1360 |
Non-return valve |
Included in F1345-40/60 |
||
-RM11-F1330 |
Non-return valve |
Included in F1345-24/30 |
||
-RM11-F1355 |
Non-return valve |
Included in F1355 |
||
-RM12-F1360 |
Non-return valve |
Included in F1345-40/60 |
||
-RM12-F1330 |
Non-return valve |
Included in F1345-24/30 |
||
-RM12-F1355 |
Non-return valve |
Included in F1355 |
||
-RM13-F1360 |
Non-return valve |
Included in F1345-40/60 |
||
-RM13-F1330 |
Non-return valve |
Included in F1345-24/30 |
||
-RM13-F1355 |
Non-return valve |
Included in F1355 |
||
-RN20 |
Trim valve |
|||
-RN21 |
Trim valve |
|||
-EB10011xx |
Heat pump system (master unit) |
F1355 |
||
-EB10012xx |
Heat pump system (master unit) |
F1345-24/30 |
||
-EB10013xx |
Heat pump system (master unit) |
F1345-40/60 |
||
-BT111xx |
Outside sensor |
Included in F1355 |
||
-BT112xx |
Outside sensor |
Included in F1345-24/30 |
||
-BT113xx |
Outside sensor |
Included in F1345-40/60 |
||
-QZ311xx |
Filterball, brine |
Included in F1355 |
||
-QZ312xx |
Filterball, brine |
Included in F1345-24/30 |
||
-EB100-BT2511xx |
External supply temperature sensor |
Included in F1355/F1345/F1355 |
||
-EB100-BT7111xx |
External return line sensor |
Included in F1355/F1345/F1355 |
||
-EB100-QZ211xx |
Filterball, heating medium |
Included in F1355 |
||
-EB100-QZ212xx |
Filterball, heating medium |
Included in F1345-24/30 |
||
-EB101 |
Heat pump system 1 |
|||
-GP16-1 |
Circulation pump, brine |
Included in F1345-24/30 40/60 |
||
-EB101-FL10 |
Safety valve, brine |
|||
-FL10-1 |
Safety valve, brine |
|||
-FL11-1 |
Safety valve, brine |
|||
-FL12-1 |
Safety valve, heating medium |
|||
-FL13-1 |
Safety valve, heating medium |
|||
-HQ1-1361 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ1-F1330-1 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ2-1362 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ2-F1330-1 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ3-1362 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ3-F1330-1 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-HQ4-1362 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ4-F1330-1 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-EB101-QM1 |
Drain valve, heating medium |
|||
-EB101-QM40 |
Shut-off valve, heating medium |
|||
-QM50-1 |
Shut off valve, brine |
|||
-QM51-1 |
Shut off valve, brine |
|||
-QM52-1 |
Shut off valve, brine |
|||
-QM53-1 |
Shut off valve, brine |
|||
-QM54-1 |
Shut-off valve, heating medium |
|||
-QM55-1 |
Shut-off valve, heating medium |
|||
-QM56-1 |
Shut-off valve, heating medium |
|||
-QM57-1 |
Shut-off valve, heating medium |
|||
-EB101-QZ2 |
Filterball, heating medium |
Included in ? |
||
-QZ2.1-1 |
Filterball, brine |
Included in F1355 |
||
-QZ2.2-1 |
Filterball, brine |
Included in F1355 |
||
-QZ2.3-1 |
Filterball, heating medium |
Included in F1355 |
||
-QZ2.4-1 |
Filterball, heating medium |
Included in F1355 |
||
-EB101-RM1 |
Non-return valve, heating medium |
|||
-RM10-F1361 |
Non-return valve |
|||
-RM10-F1330-1 |
Non-return valve |
Included in F1345-24/30 |
||
-RM10-F1355-1 |
Non-return valve |
Included in F1355 |
||
-RM11-F1361 |
Non-return valve |
Included in F1345-40/60 |
||
-RM11-F1330-1 |
Non-return valve |
Included in F1345-24/30 |
||
-RM11-F1355-1 |
Non-return valve |
Included in F1355 |
||
-RM12-F1361 |
Non-return valve |
Included in F1345-40/60 |
||
-RM12-F1330-1 |
Non-return valve |
Included in F1345-24/30 |
||
-RM12-F1355-1 |
Non-return valve |
Included in F1355 |
||
-RM13-F1361 |
Non-return valve |
Included in F1345-40/60 |
||
-RM13-F1330-1 |
Non-return valve |
Included in F1345-24/30 |
||
-RM13-F1355-1 |
Non-return valve |
Included in F1355 |
||
-EB102 |
Heat pump system 2 |
|||
-GP16-2 |
Circulation pump, brine |
Included in F1345-24/30 40/60 |
||
-EB102-FL10 |
Safety valve, heating medium |
|||
-FL10-2 |
Safety valve, brine |
|||
-FL11-2 |
Safety valve, brine |
|||
-FL12-2 |
Safety valve, heating medium |
|||
-FL13-2 |
Safety valve, heating medium |
|||
-HQ1-F1362 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ1-F1330-2 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ2-F1362 |
Particle filter, brine |
Included in F1345-40/60 |
||
-HQ2-F1330-2 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ3-F1362 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ3-F1330-2 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-HQ4-F1362 |
Particle filter, heating medium |
Included in F1345-40/60 |
||
-HQ4-F1330-2 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-EB102-QM1 |
Drain valve, heating medium |
|||
-EB102-QM40 |
Shut-off valve, heating medium |
|||
-QM50-2 |
Shut off valve, brine |
|||
-QM51-2 |
Shut off valve, brine |
|||
-QM52-2 |
Shut off valve, brine |
|||
-QM53-2 |
Shut off valve, brine |
|||
-QM54-2 |
Shut-off valve, heating medium |
|||
-QM55-2 |
Shut-off valve, heating medium |
|||
-QM56-2 |
Shut-off valve, heating medium |
|||
-QM57-2 |
Shut-off valve, heating medium |
|||
-QZ2.1-2 |
Filterball, brine |
Included in F1355 |
||
-QZ2.2-2 |
Filterball, brine |
Included in F1355 |
||
-QZ2.3-2 |
Filterball, heating medium |
Included in F1355 |
||
-QZ2.4-2 |
Filterball, heating medium |
Included in F1355 |
||
-EB102-RM1 |
Non-return valve, heating medium |
|||
-RM10-F1362 |
Non-return valve |
|||
-RM10-F1330-2 |
Non-return valve |
Included in F1345-24/30 |
||
-RM10-F1355-2 |
Non-return valve |
Included in F1355 |
||
-RM11-F1362 |
Non-return valve |
Included in F1345-40/60 |
||
-RM11-F1330-2 |
Non-return valve |
Included in F1345-24/30 |
||
-RM11-F1355-2 |
Non-return valve |
Included in F1355 |
||
-RM12-F1362 |
Non-return valve |
Included in F1345-40/60 |
||
-RM12-F1330-2 |
Non-return valve |
Included in F1345-24/30 |
||
-RM12-F1355-2 |
Non-return valve |
Included in F1355 |
||
-RM13-F1362 |
Non-return valve |
Included in F1345-40/60 |
||
-RM13-F1330-2 |
Non-return valve |
Included in F1345-24/30 |
||
-RM13-F1355-2 |
Non-return valve |
Included in F1355 |
||
-EB103 |
Heat pump system 3 |
|||
-EB103-AA25 |
AXC module |
Included in AXC 40 |
||
-EB103-FL10 |
Safety valve, heating medium |
|||
-EB103-QM1 |
Drain valve, heating medium |
|||
-EB103-QM40 |
Shut-off valve, heating medium |
|||
-EB103-RM1 |
Non-return valve, heating medium |
|||
-EB104 |
Heat pump system 4 |
|||
-EB104-FL10 |
Safety valve, heating medium |
|||
-EB104-QM1 |
Drain valve, heating medium |
|||
-EB104-QM40 |
Shut-off valve, heating medium |
|||
-EB104-RM1 |
Non-return valve, heating medium |
|||
XL1 |
Heating medium connection, supply |
|||
XL2 |
Heating medium connection, return |
|||
-AZ10.1 |
Exhaust air recovery 1 |
|||
-AZ10-GP2 |
Circulation pump, exhaust air recovery |
|||
-AZ10-RM20 |
Non-return valve, exhaust air recovery |
|||
-AZ10-RM1 |
Non-return valve, exhaust air recovery |
|||
-AZ10-RN1 |
Trim valve, exhaust air recovery |
|||
-AZ10.2 |
Exhaust air recovery 2 |
|||
-AZ10.3 |
Exhaust air recovery 3 |
|||
-AZ11 |
Ventilation module |
|||
0 |
Exhaust air module |
NIBE F135 |
||
0 |
Exhaust air module |
NIBE S135 |
||
0_SAM |
Supply air module |
NIBE SAM S42/S44 |
||
-CL11 |
Pool system |
AXC 50 |
||
-CL11_F1145 |
Pool system |
POOL 40 |
||
-CL11-AA25 |
AXC module, pool |
Included in AXC 50 |
||
-CL11-AA25_F1145 |
AXC module, pool |
Included in POOL 40 |
||
-CL11-BT25 |
External supply temperature sensor |
Included in AXC 50 |
||
-CL11-BT51 |
Pool sensor |
Included in AXC 50 |
||
-CL11-BT51_F1145 |
Pool sensor |
Included in POOL 40 |
||
-CL11-EP5 |
Exchanger, pool |
|||
-CL11-GP9 |
Circulation pump, pool |
|||
-CL11-HQ4 |
Particle filter, pool |
|||
-CL11-QN19 |
Three way valve, pool |
See the valve’s manual for a port description. |
Max. 17 kW |
|
-CL11-RM1 |
Non-return valve, pool |
|||
-CL12 |
Pool system 2 |
AXC 50 |
||
-CL12_F1145 |
Pool system 2 |
POOL 40 |
||
-CL12-AA25 |
AXC module, pool |
Included in AXC 50 |
||
-CL12-AA25_F1145 |
AXC module, pool |
Included in POOL 40 |
||
-CL12-BT25 |
External supply temperature sensor |
Included in AXC 50 |
||
-CL12-BT51 |
Pool sensor |
Included in AXC 50 |
||
-CL12-BT51_F1145 |
Pool sensor |
Included in POOL 40 |
||
-CL12-EP5 |
Exchanger, pool |
|||
-CL12-GP9 |
Circulation pump, pool |
|||
-CL12-GP12 |
Charge pump, pool |
Included in POOL 310 |
||
-CL12-HQ4 |
Particle filter, pool |
|||
-CL12-QN19 |
Three way valve, pool |
See the valve’s manual for a port description. |
Max. 17 kW |
|
-CP1 |
Storage tank |
|||
-CP1.1 |
Storage tank |
|||
-CP1.1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1.1-FL1 |
Safety valve, hot water |
|||
-CP1-FL1 |
Safety valve, hot water |
|||
-CP1.1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.2-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.2-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.1-FQ1 |
Thermal mixing valve |
|||
-CP1-FQ1 |
Thermal mixing valve |
|||
-CP1.1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1.1-QM30 |
Shut-off valve |
|||
-CP1-QM30 |
Shut-off valve |
|||
-CP1.1-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.2-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.1-RM1 |
Non-return valve |
|||
-CP1-RM1 |
Non-return valve |
|||
-CP1.1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1.1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.2-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.1-RN1.1 |
Trim valve |
|||
-CP1-RN1.1 |
Trim valve |
|||
-CP1.1-RN1.2 |
Trim valve |
|||
-CP1-RN1.2 |
Trim valve |
|||
-CP1.2 |
Storage tank |
|||
-CP1.2-RN1.1 |
Trim valve |
|||
-CP1.2-RN1.2 |
Trim valve |
|||
-RN60 |
Trim valve |
|||
-RN61 |
Trim valve |
|||
-CP2-FQ1 |
Thermal mixing valve |
Part no. 624 922 |
||
-CP4 |
Additional water heater |
|||
-CP10.4 |
Tanks |
|||
-CP10.4 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.5 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.6 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.7 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-EB1 |
Step-controlled additional heat/electric boiler |
|||
-EB1-AA25 |
AXC module |
Included in AXC 40 |
||
-EB1-AA25_F1145 |
AXC module |
Included in AXC 40 |
||
-EB1-BT25 |
Supply temperature sensor, heating medium, external |
Included in AXC 40 |
||
-EB1-BT52 |
Boiler sensor |
Included in AXC 40 |
||
-EB1-CM5 |
Closed expansion vessel, heating medium |
|||
-EB1-EP7 |
District heating exchanger |
|||
-EB1-FL2 |
Safety valve, heating medium |
|||
-EB1-GP10 |
Circulation pump, heating medium external |
|||
-EB1-QM40 |
Shut-off valve |
|||
-EB1-QM41 |
Shut-off valve |
|||
-EB1-QN11 |
Shuttle valve |
See the valve’s manual for a port description. |
||
-EB1-RM5 |
Non-return valve |
|||
-RN1 |
Trim valve |
|||
-EB2 |
External electrical backup |
|||
-EB3 |
Immersion heater in tank |
with junction box K11 |
IU 3 kW: 695 20 30 IU 6 kW: 695 20 71 IU 9 kW: 695 20 97 K11: 695 22 38 |
|
-EB3-QA1 |
Auxiliary relay |
HR 10 |
||
-EB15 |
Indoor module |
F1345/F1355 |
||
-EB15-BT1 |
Outside sensor |
Included in F1345/F1355 |
||
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
||
-EB15-CM4 |
Expansion vessel, hot water |
|||
-EB15-GP10 |
Circulation pump, heating medium external |
|||
-EB15-FL1 |
Safety valve, hot water |
|||
-EB15-RM2 |
Non-return valve |
|||
-EB15-QM30 |
Shut-off valve, hot water |
|||
-EB15-WM4 |
Tundish, T&P valve |
Included in F1345/F1355 |
||
XL |
XL connections |
|||
1 |
Heating medium connection, supply |
|||
2 |
Heating medium connection, return |
|||
3 |
Cold water connection |
|||
4 |
Hot water connection |
|||
5 |
Hot water circulation connection |
|||
6 |
Brine connection, supply |
|||
7 |
Brine connection, return |
|||
8 |
Docking connection, supply (from heat pump) |
|||
9 |
Docking connection, return (to heat pump) |
|||
13 |
Solar heat connection, supply |
|||
14 |
Solar heat connection, return |
|||
18 |
Docking connection, supply (from heat pump) |
|||
19 |
Docking connection, return (to heat pump) |
|||
29 |
T&Pvalve |
|||
30 |
Expansion vessel connection |
|||
36 |
Heating medium connection, supply |
|||
37 |
Heating medium connection, return |
|||
39 |
Docking connection, pool |
|||
-EM1 |
Shunt controlled additional heat |
|||
-EM1-AA25 |
AXC module |
Included in AXC 40 |
||
-EM1-QN11 |
Shunt valve for additional heat |
|||
-EM1-BT52 |
Boiler sensor |
|||
-EM1-BT25 |
Supply temperature sensor, heating medium, external |
Included in AXC 40 |
||
-EM1-GP10 |
External heating medium pump |
|||
-EM1/EB1 |
Electric boiler, wood boiler, pellet boiler, oil boiler or district heating |
|||
-EM1/EB1-GP10 |
Circulation pump |
|||
-EP1 |
District heating |
|||
-EP1-AA25 |
AXC module |
Included in AXC 40 |
||
-EP1-BT25 |
External supply temperature sensor |
Included in AXC 40 |
||
-EP1-BT52 |
Boiler sensor |
Included in AXC 40 |
||
-EP1-CM5 |
Closed expansion vessel, heating medium |
|||
-EP1-EP3 |
District heating exchanger, hot water |
|||
-EP1-EP7 |
District heating exchanger |
|||
-EP1-FL2 |
Safety valve, heating medium |
|||
-EP1-QN11 |
Mixing valve, addition |
See the valve’s manual for a port description. |
||
-EP1-RM1 |
Non-return valve |
|||
-EP1-CT1 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT2 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT3 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP10 |
Shunt controlled brine |
|||
-EP10-AA25 |
AXC module |
Included in AXC 40 |
||
-EP10-BT26 |
Temperature sensor, brine in |
Included in AXC 40 |
||
-EP10-QN41 |
Shunt valve, brine |
See the valve’s manual for a port description. |
||
-EP10-EP10 |
Heat exchanger |
|||
-EP12 |
Ground water system |
|||
-EP12-AA25 |
AXC module, groundwater |
Included in AXC 40 |
||
-EP12-EP4 |
Groundwater exchanger |
|||
-EP12-GP3 |
Circulation pump, groundwater |
|||
-EP12-HQ40 |
Particle filter, groundwater |
|||
-EP21 |
Heating system 2 |
AXC 50 |
||
-EP21-AA25 |
AXC module, heating system 2 |
Included in AXC 50 |
||
-EP21-BT2 |
Supply temperature sensor, heating system 2 |
Included in AXC 50 |
||
-EP21-BT3 |
Return line sensor, heating system 2 |
Included in AXC 50 |
||
-EP21-GP10 |
Circulation pump, heating system 2 |
|||
-EP21-QN25 |
Shunt valve, heating system 2 |
See the valve’s manual for a port description. |
||
-EP21-RM1 |
Non-return valve |
|||
-EP22 |
Heating system 3 |
AXC 50 |
||
K |
Climate system 3 |
AXC 50 |
||
-EP22-AA25 |
AXC module, heating system 3 |
Included in AXC 50 |
||
-EP22-BT2 |
Supply temperature sensor, heating system 3 |
Included in AXC 50 |
||
-EP22-BT3 |
Return line sensor, heating system 3 |
Included in AXC 50 |
||
-EP22-GP10 |
Circulation pump, heating system 3 |
|||
-EP22-QN25 |
Shunt valve, heating system 3 |
See the valve’s manual for a port description. |
||
-EP22-RM1 |
Non-return valve |
|||
-EP30 |
Solar heating system |
SCA 35 |
||
-EP30-AA25 |
AXC module |
Included in SCA 35 |
||
-EP8 |
Solar panels |
|||
-EP30-EP9 |
Exchanger, solar |
|||
-EP30-GP10 |
Circulation pump |
|||
-EP44 |
Cooling system 1 |
AXC 50 |
||
-EP44-AA25 |
AXC module, cooling system 1 |
Included in AXC 50 |
||
-EP44-BT2 |
Supply temperature sensor, cooling system 1 |
|||
-EP44-BT3 |
Return line sensor, cooling system 1 |
|||
-EP44-BT64 |
Flow temperature sensor, cooling |
Included in AXC 50 |
||
-EP44-BT65 |
Return line sensor, cooling |
Included in AXC 50 |
||
-EP44-GP10 |
Circulation pump, cooling system 1 |
|||
-EP44-QN18 |
Shunt valve, cooling system 1 |
See the valve’s manual for a port description. |
||
-EP44-RM1 |
Non-return valve |
|||
-EP45 |
Cooling system 1 |
|||
-EP45-AA25 |
AXC module, cooling system 1 |
Included in AXC 40 |
||
-EP45-GP10 |
Circulation pump, cooling system 1 |
|||
-EP45-QN12 |
Reversing valve, cooling |
See the valve’s manual for a port description. |
||
-EP25 |
Passive cooling system |
AXC 50 |
||
-EP25-AA25 |
AXC module, cooling |
Included in AXC 50 |
||
-EP25-BT64 |
Temperature sensor, cooling flow line |
Included in AXC 50 |
||
-EP25-BT65 |
Temperature sensor, cooling return line |
Included in AXC 50 |
||
-EP25-EP13 |
Supply air coil/fan coil |
|||
-EP25-GP13 |
Circulation pump, cooling |
|||
-EP25-QN18 |
Mixing valve, cooling |
See the valve’s manual for a port description. |
||
-EP25-RM1 |
Non-return valve |
|||
-EQ1 |
Active cooling. |
NIBE ACS 45 |
||
-EQ1-AA25 |
AXC module, cooling |
Included in NIBE ACS 45 |
||
-EQ1-BT57 |
Temperature sensor, collector |
Included in NIBE ACS 45 |
||
-EQ1-BT64 |
Flow temperature sensor, cooling |
Included in NIBE ACS 45 |
||
-EQ1-BT75 |
Temperature sensor, flow line after heat dump |
Included in NIBE ACS 45 |
||
-EQ1-EP6 |
Heat exchanger |
|||
-EQ1-GP10 |
Circulation pump |
|||
-EQ1-GP12 |
Circulation pump |
Included in NIBE ACS 45 |
||
-EQ1-GP14 |
Circulation pump for heat dump |
|||
-EQ1-GP20 |
Circulation pump, heat dump |
|||
-EQ1-QM40.1 |
Shut-off valve |
|||
-EQ1-QM40.2 |
Shut-off valve |
|||
-EQ1-QN12 |
Reversing valve, cooling |
See the valve’s manual for a port description. |
||
-EQ1-QN18 |
Shunt valve, cooling shunt |
See the valve’s manual for a port description. |
||
-EQ1-QN36 |
Shunt valve, heating shunt |
See the valve’s manual for a port description. |
||
-EQ1-RM1 |
Non-return valve, heat dump |
|||
-EZ2 |
Domestic hot water module |
Cetetherm AquaEfficiency |
Cetetherm AB |
|
-QZ1 |
Hot water circulation (HWC) |
|||
-QZ1-AA25 |
AXC module |
Included in AXC 40 |
||
-QZ1-AA25 |
AXC module |
Included in AXC 40 |
||
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in AXC 40 |
||
-QZ1-BT82 |
Return line sensor, HWC |
Included in AXC 40 |
||
-QZ1-FQ3 |
Mixer valve, HWC |
|||
-QZ1-GP11 |
Circulation pump, HWC |
|||
-QZ1-QN2 |
4-way valve, HWC |
See the valve’s manual for a port description. |
||
-QZ1-RM1 |
Non-return valve, HWC |
|||
-QZ1-RN1 |
Trim valve, HWC |
|||
-QZ1-RN4 |
Trim valve, HWC |
|||
-XL27 |
Filling connection |
|||
-QM33 |
Shut off valve, brine flow |
|||
-XL27 |
Filling brine |
|||
-XL28 |
Filling brine |
|||
-FL2 |
Miscellaneous |
|||
-RN1.1 |
Miscellaneous |
|||
-AA25 |
Accessory card |
AXC 40 |
Required if the groundwater pump or hot water circulation pump is to be connected to F1345/F1355 at the same time as the common alarm. The relay outputs on the accessory board can have a max. load of 2 A (230 V) in total. |
|
-BP5 |
Pressure gauge, heating medium |
|||
-BP6 |
Pressure gauge, brine |
|||
-CM1 |
Expansion vessel, heating medium |
|||
-CM2_F1145 |
Level vessel, brine |
Included in S1155/F1155/F1145 |
Level vessel in open system |
|
-CM2_F1245 |
Level vessel, brine |
Included in S1255/F1255/F1245 |
Level vessel in open system |
|
-CM3 |
Expansion vessel, brine |
|||
-CM4 |
Expansion vessel, hot water |
Included in F1345/F1355 |
||
-CP10 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-CP10.1 |
Buffer vessel |
UKV |
Size varies depending on heat pump and system volume |
|
-CP10.2 |
Buffer vessel, cooling |
UKV |
Condensation-insulated vessels for cooling Size varies depending on heat pump and system volume |
|
-CP10.3 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-FL1 |
Safety valve, hot water |
|||
-FL2 |
Safety valve, heating medium |
|||
-FQ1 |
Mixing valve |
Thermal |
||
-HQ1 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ2 |
Particle filter, brine |
Included in F1345-24/30 |
||
-HQ3 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-HQ4 |
Particle filter, heating medium |
Included in F1345-24/30 |
||
-RM1 |
Non-return valve |
|||
-RM1.1 |
Non-return valve |
|||
-RM1.2 |
Non-return valve |
|||
-RM1.3 |
Non-return valve |
|||
-RM2 |
Non-return valve |
|||
-RM3 |
Non-return valve |
|||
-RN1.1 |
Trim valve |
|||
-RN1.2 |
Trim valve |
|||
-RN1.3 |
Trim valve |
|||
-RN2.1 |
Trim valve |
|||
-RN2.2 |
Trim valve |
|||
-RN3.1 |
Trim valve |
|||
-RN3.2 |
Trim valve |
|||
-RN4.1 |
Trim valve |
|||
-RN4.2 |
Trim valve |
|||
-RN5.1 |
Trim valve |
|||
-RN5.2 |
Trim valve |
|||
-QM1 |
Drain valve, heating medium |
|||
-QM30 |
Shut-off valve, hot water |
|||
-QN17 |
Pressure reduction valve |
|||
-WM3 |
Tundish, cold water |
Included in F1345/F1355 |
||
-WM4 |
Tundish, T&P valve |
Included in F1345/F1355 |
||
-WP5_S43 |
Docking kit DEW S43 |
|||
-WP5-AA25_S43 |